YC Diesel Engines

YC Diesel Generators Sizes 

20 KVA
30 KVA
40 KVA
60 KVA
80 KVA
100 KVA

 

135 KVA
150 KVA
180 KVA
250 KVA
300 KVA
625 KVA

About YC Diesel Engines

Founded in 1951, Guangxi Yuchai Machinery Group Co., Ltd. (Yuchai Group for short) is headquartered in Yulin, Guangxi Zhuang Autonomous Region. It is an investment and financing management company centered on capital operation and assets management. As a large-scale state-owned enterprise group, Yuchai Group has more than 30 wholly-owned, holding, and joint stock subsidiaries, with total assets of CNY 42.9 billion and approximately 16, 000 employees. Yuchai Group is an internal combustion engine manufacturing base with a complete range of products in China. It has industrial base layout in Guangxi, Guangdong, Jiangsu, Anhui, Shandong, Hubei, Sichuan, Chongqing and Liaoning. Its annual sales volume is nearly CNY 50 billion and its sales volume of engines has ranked among the top in the industry for consecutive years.

Yuchai is on the list of the China′s Top 500 Enterprises and China′s Top 500 Manufacturing Enterprises. It ranks 10th among the top 100 Enterprises in China′s Machinery Industry, and the 99th among China′s 500 Most Valuable Brands, with a brand value exceeding 63.825 billion Yuan. Honored with the "Autonomous Region Chairman Quality Award" and "China Quality Award Nomination Award", Yuchai is a national demonstration base for corporate culture construction and a national civilized unit, which has released corporate sustainable development reports for 13 consecutive years.

Guangxi Yuchai International Trade Co., Ltd. is a subsidiary company of Yuchai Group, which mainly engaged in the export of products of the Yuchai Group, including engines, generator sets, excavators, logging machines, light trucks and coaches (including traction, cargo), oil products, accessories and tires. The company also undertakes the overseas export business of whole vehicle products equipped with Yuchai engines, such as commercial vehicles, agricultural machinery, construction machinery and so on, to assist the whole vehicle manufacturers with overseas distribution channel development.

Alternator Specs

Werna/Evotech Alternator or Equal

Condition: New product
Phase: 3 Phase / Single Phase
Frequency: 50 Hz
Voltage: 220 - 240v Single Phase
Protection: IP23
Rpm speed: 1500 rpm
Poles: 4
Efficiency: 94.8%
Constant speed alternator
Brushless
Voltage regulator: AVR

Controller System Specs

Smartgen Controller

SmartGen generator controllers are used for automatic and monitor control system of gen-set to achieve automatic start/stop, data measure and alarm protection. The controller adopts large liquid crystal display (LCD) and selectable Chinese, English or other languages interface with easy and reliable operation.

Gen-set automatic controllers adopt 32 bits microprocessor technology with precision parameters measuring, fixed value adjustment, time setting and
threshold adjusting and etc.. Majority parameters can be configured from front panel, and all parameters can be configured by USB interface (or RS485/Link interface) to adjust via PC. It can be widely used in all types of automatic gen-set control system with compact structure, advanced circuits, simple connections and high reliability.

Warranties & Other Info

ENGINE MECHANICAL WARRANTY 2YEAR / 2000 HRS
From date of collection/Delivery
Warranty is only on Mechanical Parts not on Electrical Components
Warranty only applies if service schedule is maintained
Warranty Void: Electrical cable are connected correctly
Generator overload, abused or the machine is glazing(Under Load or Unbalance Phasing ).

SERVICE SCHEDULE:
50 hrs oil and oil filter change
First Service: 250 hrs /3 Months
Second Service: 500 hrs /6 Months
Third Service: 750 hrs /9 Months
Fourth Service: 1000 hrs /1Year

Engine must be serviced every 250 hours or 3 months for warranty.
Continue once a year or 500 / 1000hrs

AUTOMATIC START: 10 SECONDS DELAY,  10 TO 35 SECONDS WARMUP

PLEASE NOTE: Generator must not run less than 35% of load for long periods this will cause glazing. All ratings are approximate and at SEA LEVEL. Engines need to be derated for altitude. A rough guide to de-rate performance is 1% for every 100m above sea level. I.e: A 20KVA at sea level is an 18KVA at 1000m above sea level (10% less) etc.

The generator will not be able to take the full load instantaneously. The load should be added to the generator gradually. 50% initially and then stepped up over time once the engine is up to temperature.

Gentech SA has different canopies. Canopy of Generator depends on availability and what is in stock.

Follow us on social media for promotions

Facebook

Contact Us

Gauteng
Head Office / Factory:
Tel: 010 012 6020
Email: sales@gentechsa.co.za
126 Birch RD cnr Larch
Benoni AH
Benoni 1509

Western Cape
Office / Factory:
Tel: 010 012 6021
Email: salescpt@gentechsa.co.za
2 Caledon Industrial Park,
14 Meul Street,
George Industrial

 

Quote me on a YC Diesel Generator

Please note we only do installations in Gauteng area.