Where a 500 kVA Volvo Penta generator fits
Large industrial, infrastructure and high-capacity standby projects where load sequencing, ventilation, fuel autonomy, site access and installation planning form part of the complete generator solution.
The 500 kVA Volvo Penta diesel generator is configured by GenTech SA around the confirmed Volvo Penta engine platform, SmartGen automatic control and automatic mains-failure changeover supplied as standard. Faraday / Werna or equivalent is supplied as the standard alternator configuration, with Mecc Alte and Leroy-Somer available as quoted upgrades.
GenTech SA supplies the generator configured for mains-failure or solar-ready operation, with an automatic changeover switch included as standard, nationwide delivery options and commissioning support.

| Engine model | VOLVO PENTA TAD1346GE |
|---|---|
| Engine manufacturer | Volvo Penta |
| Cylinders | 6 |
| Cylinder bore / stroke | 131 × 158 mm |
| Displacement | 12.78 L |
| Engine output @ 1500 rpm | 439 kW PRP |
| Aspiration | Turbocharged |
| Compression ratio | 17.8:1 |
| Engine speed | 1500 RPM |
| Cycle | 4-stroke diesel |
| Cooling method | Water cooled |
| Governor system | Volvo / EMS 2.4 |
| Starter system | 24 V, 7.0 kW |
| Oil capacity | 36 L |
| Coolant capacity | 48 L |
| Fuel tank capacity | 600 L |
| Generator output class | 500 kVA |
|---|---|
| Standard alternator | Faraday / Werna or equivalent quality |
| Premium alternator options | Mecc Alte / Leroy-Somer — quoted on request |
| Alternator type | Brushless |
| Phase configuration | Three phase |
| Rated voltage | 380–400 V |
| Rated frequency | 50 Hz |
| Speed | 1500 RPM |
| Automatic Voltage Regulator | AVR included |
| Protection class | IP23 |
| Controller | SmartGen automatic generator controller |
| ATS / automatic changeover | Included as standard |
| Mechanical warranty | 1 year / 1,000 hours, whichever occurs first, subject to GenTech SA warranty conditions. |
|---|---|
| First service | 50 hours / 3 months |
| Second service | 200 hours / 6 months |
| Third service | 550 hours / 12 months |
| Ongoing service | Annually or every 500 to 1,000 hours, subject to operating conditions. |
| Enclosure | Sound-attenuated enclosure; alternative configurations can be quoted. |
| Delivery | Nationwide delivery enquiries welcome. |
| Installation | GenTech SA installation service currently offered in Gauteng. |
GenTech SA supplies the 500 kVA Volvo Penta diesel generator around the confirmed Volvo Penta engine specification and the requirements of the application. Engine output on this page is shown using the PRP prime-power rating. Correct sizing should consider running kW, motor starting current, power factor, altitude, operating hours and site conditions.
Large industrial, infrastructure and high-capacity standby projects where load sequencing, ventilation, fuel autonomy, site access and installation planning form part of the complete generator solution.
ATS / automatic changeover is included as standard for mains-failure operation. The generator can also be configured for solar-ready operation where the site control system calls the generator for load support or battery charging.
GenTech SA supports supplied generator sets with scheduled servicing, repairs, fault finding, replacement parts and technical assistance. Service access, operating conditions and long-term support should be considered when planning the installation.
Generator selection should be based on the real electrical load rather than kVA alone. Motors, pumps, compressors, refrigeration and machinery can have high starting currents, while altitude and power factor can reduce operating margin.
Faraday / Werna or equivalent quality is the standard alternator configuration, with Mecc Alte and Leroy-Somer available as quoted upgrades. Open-type, sound-attenuated and project-specific enclosure arrangements can be considered according to the application.
GenTech SA welcomes Volvo Penta generator enquiries throughout South Africa and selected African export markets. Transport, off-loading and project requirements are confirmed according to generator size, destination and scope.
Yes. GenTech SA includes ATS / automatic mains-failure changeover as standard on the generator build.
The engine output is shown using the Volvo Penta PRP prime-power rating.
That depends on running load, motor and compressor starting current, operating pattern, altitude, power factor and site conditions. GenTech SA can review the application before quotation.
Yes. Nationwide delivery enquiries are welcome, and selected African export requirements can also be quoted.
Complete the form below to request pricing for this generator. The selected model will be included automatically with your enquiry.
ATS / AMF: automatic mains-failure changeover is included as standard on GenTech SA generators.